国产一区二区三区波多野结衣AV_日韩午夜在线视频_俺去啦最新官网在线_国产无夜激无码AV毛片_日韩午夜精品毛片_国产在线高清无码视频_中文 国产 亚洲 喷潮_2017最新理论电影在线_波多野给衣一区二区三区_成年女人毛片视频免费

您好,歡迎光臨上海恒遠生物科技商城!
全國服務熱線:18221290082
關(guān)注我們

快速導航

首頁 > 產(chǎn)品文獻

恒遠產(chǎn)品技術(shù)文獻:魚丙二醛(MDA)ELISA試劑盒引用文獻
發(fā)布時間:2021/9/13 11:14:38 閱讀次數(shù):612

 【文獻標題】Chronic exposure to low environmental concentrations and legal aquaculture doses of antibiotics cause systemic adverse effects in Nile tilapia and provoke differential human health risk

【作者】Samwel M. Limbu,Li Zhou,Sheng-Xiang Sun,et.al

【作者單位】華東師范大學(East China Normal University)
【文獻中引用產(chǎn)品】
魚丙二醛(MDA)ELISA試劑盒
【關(guān)鍵詞】Low environmental antibiotics,Legal aquaculture antibiotics,Toxicological effects,Human health risk
【DOI】https://doi.org/10.1016/j.envint.2018.03.034
【影響因子(IF)】8.58
出版期刊】《Environment International》
【產(chǎn)品原文引用】
After weight measurements and counting, eight fish from each tank were sampled, individually anesthetized with MS-222 (20 mg/L) (tricaine methanesulfonate, Western Chemicals, Inc., Ferndale,Washington) and sacrificed for tissue samples collection for biochemical assays, nutrients body composition and digestibility measurements.Intestines, livers and skins from O. niloticus were excised and subsequently homogenized in a glass beds with 9 volumes (v/w) of 0.8% physiological saline. The homogenate was centrifuged (2500 rpm, at 4 °C for 10 min), the resulting supernatant was collected and subsequently frozen at ?80 °C for biochemical assays according to manufacturers' instructions. One whole intestine, liver and a piece of skin from each fish were used in all analyses. On the days of analyses,malondialdehyde (MDA) concentration was determined by using enzyme-linked immune sorbent assay (ELISA) kit (Hengyuan, Shanghai).Protease, lipase, amylase, lactate dehydrogenase (LDH), glutathione Stransferase (GST), superoxide dismutase (SOD), total antioxidant capacity (TAC), acid phosphatase (ACP), and alkaline phosphatase (AKP)were measured by using specific commercial assay kits (Nanjing Jiancheng Institute, China), with their results recorded on a microplate reader (Epoch, BioTek, USA). The remaining fish (with viscera removed) were used for body composition and apparent nutrients digestibility measurements according to standard methods (AOAC, 1995).

完整版PDF文獻請咨詢在線客服或者電話聯(lián)系我司業(yè)務員!
更多公司福利請關(guān)注“恒遠生物”微信公眾號!
首頁|產(chǎn)品專區(qū)|品牌專區(qū)|優(yōu)惠促銷|產(chǎn)品文獻|公司簡介|付款方式

關(guān)注恒遠生物科技

服務熱線:

18221290082

13636351073

13564766906

13636351217

18221656311

13817140470